Rated frequency: 50Hz 
Rated residual operating current: 50/75/100/150/200/300/500/800/1000mA, 
rated residual non-operating current 0.5I¡÷n: Abrupt leakage action value: ¡Ü50mA Single product only uses four For each gear, please refer to the value on the nameplate. 
Rated breaking time: <0.2s/<0.5s can be set to automatically reclose once from 20s to 60s
	Delayed reclosing time: 70% of rated voltage, 
undervoltage action value: 120% of rated voltage (can be closed) 
, overvoltage action value: action when any phase of ABC three-phase is missing (can be closed); 
phase failure protection: functional module The power supply is directly taken from the three-phase power supply of the autonomous loop, which completely avoids the problem of phase loss and residual current protection not working.
	Note*: The neutral pole (N pole) of the four-level product is divided into four types of 
A-type N-pole, no overcurrent tripping element is installed, and the N-pole is always on, not combined with other three-level; 
B-type N-pole No overcurrent trip element is installed, and the N pole is combined with other three levels (N pole is closed first and then opened); 
C-type N pole is installed with overcurrent trip element, and the N pole is combined with other three levels (N The pole is closed first and then opened); 
D-type N pole is installed with an overcurrent trip element, and the N pole is always on, and does not open and close together with other three levels;
	1. The upper limit of ambient air temperature is +40¡æ, the lower limit is -5¡æ, and the average value of 24h does not exceed +35¡æ. 
2. Altitude: The altitude of the installation site does not exceed 2000m. 
3. Relative humidity: the relative humidity of the atmosphere does not exceed 50% when the ambient air temperature is +40¡æ, and it can have a higher relative humidity at a lower temperature; the monthly average maximum relative humidity of the wettest month is 90%, and the The monthly average minimum temperature of the month is +25¡ãC, taking into account the condensation on the surface of the product due to temperature changes. 
4. Pollution degree: Pollution degree is 3
	1. Ambient temperature: ambient air temperature is -5¡ãC-+40¡ãC (special order must be negotiated with the manufacturer); 
2. Altitude: The altitude of the installation site is 2000mm; 
3. Pollution degree: Pollution degree is 3; 
4. Installation position: it should be installed vertically, with an inclination not exceeding 5¡ã;
	1. Altitude: no more than 2000m; 
2. Ambient temperature: -5¡ãC~+40¡ãC, the average value of 24h does not exceed 35¡ãC. If it exceeds this range, please consult with the manufacturer; 
3. Relative humidity: no more than 50% when the maximum temperature is +40¡æ, and the maximum relative humidity is 90% (20¡æ). Special measures must be taken for condensation on the product due to temperature changes; 
4. Pollution level: Level 2;
Share our Product over the Social Networks
Search across our website